Mean Well LRS-150F-24 156W AC/DC Enclosed Power Supply
ITE & Household - Single Output Switching - 24V, 6.5A
Out of stock
Mean Well LRS-150F-24 156W AC/DC Enclosed Power Supply
ITE & Household - Single Output Switching - 24V, 6.5A
- Brand: Mean Well
- MPN: 2815980
- Part #: PSUMWL150F24
- UPC:
- Brand: Mean Well
- MPN: 2815980
- Part #: PSUMWL150F24
- UPC:
What PB Tech customers are saying about this product...
See More Reviews"Very good product, just what I needed for my little project"
Features
Specifications
Reviews
Delivery & Pick-up
Returns & Warranty
Popular Server Power Supplies
Mean Well LRS-150F-24 156W AC/DC Enclosed Power Supply ITE & Household - Single Output Switching - 24V, 6.5A
- Brand: Mean Well
- MPN: 2815980
- Part #: PSUMWL150F24
Product URL: https://www.pbtech.com/product/PSUMWL150F24/returns
Features
LRS-150F series is a 150W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85-264VAC input, the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-150F that the whole series operates from -30°C through 70°C under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.5W), it allows the end system to easily meet the worldwide energy requirement. LRS-150F has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV EN60950-1, EN60335-1,EN61558-1/-2-16, UL60950-1 and GB4943. LRS-150F series serves as a high price-toperformance power supply solution for various industrial applications.
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.5W
- Miniature size and 1U low profile
- High operating temperature up to 70°C
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Compliance to IEC/EN 60335-1(PD3) and IEC/EN61558-1, 2-16 for household appliances
- Operating altitude up to 5000 meters
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- 100% full load burn-in test
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
Specifications
OUTPUT
DC VOLTAGE
24V
RATED CURRENT
6.5A
CURRENT RANGE
0 - 6.5A
RATED POWER
156W
RIPPLE & NOISE (max.) Note.2
200mVp-p
VOLTAGE ADJ. RANGE
21.6 - 28.8V
VOLTAGE TOLERANCE Note.3
1.0%
LINE REGULATION Note.4
0.5
LOAD REGULATION Note.5
0.5%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 12ms/115VAC at full load
INPUT
VOLTAGE RANGE
85 - 264VAC 120 - 370VDC
FREQUENCY RANGE
47 - 63Hz
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
2.8A/115VAC 1.6A/230VAC
INRUSH CURRENT (Typ.)
COLD STAR 60A/230VAC
LEAKAGE CURRENT
<0.75mA/ 240VAC
PROTECTION
OVER LOAD
110 - 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
28.8 - 33.6V
Protection type : Shut down olp voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
-30 - +70deg;C (Refer to 'Derating Curve')
WORKING HUMIDITY
20 - 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 - +85 deg;C, 10 - 95% RH
TEMP. COEFFICIENT
0.03%/deg;C (0 - 50°C)
VIBRATION
10 - 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OTHERS
MTBF
648.6K hrs min. MIL-HDBK-217F (25°C)
DIMENSION
159'97'30mm (L*W"H)
PACKING
0.48Kg ; 30pcs/15.4Kg/0.75CUFT
NOTE
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm"360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on httpiIwww.meanwell.com) 8. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m (6500ft).