FLUKE 26500610 TS100 Metric Cable F Finder TDR, BNC To Alligator Clips.
Out of stock
FLUKE 26500610 TS100 Metric Cable F Finder TDR, BNC To Alligator Clips.
- Brand: FLUKE
- MPN: 26500610
- Part #: TOLFLN39242
- UPC: 754082039242
View all shipping info
- Brand: FLUKE
- MPN: 26500610
- Part #: TOLFLN39242
- UPC: 754082039242
Features
Specifications
Reviews
Delivery & Pick-up
Returns & Warranty
Popular Testing & Measurement Tools





FLUKE 26500610 TS100 Metric Cable F Finder TDR, BNC To Alligator Clips.
- Brand: FLUKE
- MPN: 26500610
- Part #: TOLFLN39242
- UPC:754082039242

Product URL: https://www.pbtech.com/au/product/TOLFLN39242/FLUKE-26500610-TS100-Metric-Cable-F-Finder-TDR-BNC
Features
FLUKE NETWORKS TS100 Metric Cable F Finder TDR, BNC To Alligator Clips
From just ONE END of any two or more conductor cables, you can measure up to 915 meters. The TS 100 cable fault locator lets you easily find the distance to opens or shorts on electrical wires, telephone wires, security wires and coax. Results appear as a distance reading rather than a waveform, so it's perfect for technicians unfamiliar with Time Domain Reflectometry (TDR).
Locate and fix cable problems without pulling new wires or blindly cutting into walls. Intermittent faults are easier to find because the unit constantly measures while "On".
The TS 100 cable fault locator is perfect for inventory management of cable stock in trucks and warehouses and it can help you generate more accurate bids for jobs by quickly assessing needs and managing the cable stock with greater accuracy.
Patented SmartTone technology gives you 5 distinct tones to use for exact wire and pair identification, even in proximity to current-bearing cable.
When touching the wires together and momentarily shorting the far end of a cable pair, the SmartTone technology will change the cadence of the tone generated. This tone change you hear through the probe positively verifies the correct wire pair.
Voltage detection in the unit will immediately sound an alarm if you accidentally clip onto an energized pair, up to 250VAC.
- 26500610 TS100 Metric Cable Fault Finder
- Works on any two or more conductor cables up to 915 meters
- Instantly measures the distance to open or any fault from one end of any cable pair
- Patented SmartTone tone generator positively identifies pair
- Measures cable distance on a spool
- Measures constantly while "On"
- Displays distance reading rather than waveform
- Large bright LED screen
- One button operation
- High voltage detection
- Moisture-proof
- Additional line cord options available for coaxial cable (F-connectors) and other applications
Specifications
General Speciffications
Power
4 AA alkaline batteries, provide 50 hours of operation.
Reverse Battery Protection
No damage to the tester will occur if the batteries are installed backwards.
Input Protection
250 V rms ac, continuous or intermittent
Moisture
If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the information on moisture under "Maintenance".
Impedance Range
35 Ohm to 330 Ohm with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings.
Maximum Length
2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display -Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length
2500 feet: CAT-5 Twisted Pair 2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet: RG-174/U Coax
Minimum Length
No minimum length Minimum non-zero reading is 2 feet
Length Accuracy
±2 feet for cables less than 10 feet ±5 feet for cables longer than 10 feet and shorter than 200 feet ±3 % and ±5 feet for cables longer than 200 feet
High Voltage Detection
An ac voltage of more than 5 V rms will trigger the High Voltage Warning.
Measurement Rate
Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP
Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed
Measurement Technology
Time Domain Reflectometry (TDR) with 50 O drive impedance, 6 V maximum pulse height
Low Battery
Indicator flashes when battery voltage falls below 4.1 V
Tone Injection
Approximately 1 kHz at an amplitude of 80 % of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to "normal-open" from any other condition.
Cable Type
Virtually all two or more conductor cables
Temperature Range
Operating Storage
32 °F to 131 °F (0 °C to 55 °C) -40 °F to 158 °F (-40 °C to 70°C)
Humidity
Operating
0 % to 80 %
Storage
0 % to 100 %
Weight
1 lb
Certifications and Compliance
CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1