PowerShield PSCERT2000SB Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime
Out of stock
PowerShield PSCERT2000SB Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime
- Brand: PowerShield
- MPN: PSCERT2000SB
- Part #: UPSPSD2002
- UPC:
View all shipping info
- Brand: PowerShield
- MPN: PSCERT2000SB
- Part #: UPSPSD2002
- UPC:
What PB Tech customers are saying about this product...
See More Reviews
"Took me about 10 minutes to attach the rack mounts and insert into the rack.
Turned it all on and plugged the USB cable into the NAS.
NAS auto configured the UPS shutdown control ...view more"
Features
Specifications
Reviews
Delivery & Pick-up
Returns & Warranty
Popular UPS - Offline / Standby





PowerShield PSCERT2000SB Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime
- Brand: PowerShield
- MPN: PSCERT2000SB
- Part #: UPSPSD2002

Product URL: https://www.pbtech.com/au/product/UPSPSD2002/PowerShield-PSCERT2000SB-Centurion-RT-2000VA--1800
Features
POWERSHIELD Centurion RT 2000VA / 1800W Short Base Double Conversion True Online UPS. Power Factor 0.9 Rack/Tower Design (2RU) Hot-Swappable Battery. EBM Compatible to Extend Runtime
The Centurion RT features True Online Double Conversion. As our highest single phase power density UPS, this sophisticated range provides the most comprehensive protection for mission-critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications
- Exceptional surge protection
- Output power factor
- Informative & easy-shift LCD display
- Rack/Tower design
- Programmable outlets
- Emergency Power Off Function (EPO)
- ECO & advanced ECO mode
- Standard extra large charger
- Hot swappable batteries
*PSRTBB8 Extended Battery Module not included
Exceptional surge protection
Offering the best surge protection in its class to protect against damaging surges
Output power factor
The Centurion RT is high-density UPS with output power factor (PF = 0.9) to provide higher performance and efficiency to critical applications.
Informative & easy-shift LCD display
The front panel LCD display panel is readily viewable whether the UPS is horizontal or vertical. It displays all critical and noncritical parameters, including remaining battery backup time.
Rack/Tower design
The Centurion RT can be easily installed as a floor-standing tower or in a 19-inch rack.
Programmable outlets
This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items.
Emergency Power Off Function (EPO)
This feature can turn off and isolate the UPS in the event of fires or other emergencies.
ECO & advanced ECO mode
It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode.
Standard extra large charger
- The Centurion RT has been designed with a larger charger than other UPSs ensuring rapid recharge times when adding additional battery banks.
- Long run models available.
Hot swappable batteries
Battery banks are hot-swappable. This keeps the UPS operational during battery replacement. Battery banks can be added to increase battery backup time.
Specifications
Capacity | 2000VA/1800W |
Topology | True online double- conversion, Pure Sine Wave |
Input | |
Voltage Range |
Low Line Transfer: 160Vac/140Vac/120/110Vac ±5% (based on load percentage 100%-80%/80%-70%/70%-60%/60%-0) Low Line Comeback: 175Vac/155Vac/135Vac/125Vac ±5 % High Line Transfer: 300Vac ±5 % High Line Comeback: 290Vac ±5 % |
Frequency Range | 40Hz - 70Hz |
Phase | Single-phase with ground |
Power Factor Correction | =0.99 @ nominal voltage (100% load) |
Output | |
Output Power Factor | 0.9 |
Output Voltage (AC Mode) | 240Vac (Selectable 200/208/220/230/240Vac) |
Voltage Regulation (Batt. Mode) | ±1% |
Frequency Range (Batt. Mode) | 50Hz or 60Hz ±1Hz |
Current Crest Ratio | 3:1 (max.) |
Transfer |
AC Mode to Batt. Mode: 0 |
Waveform (Batt. Mode) |
Pure Sine Wave |
Efficiency | |
ECO Mode (Advanced) | 97% |
Battery Mode | 87% |
Battery | |
Battery Number (12 V*9AH) | x4 |
Typical Recharge Time | 4 hours recover to 90% capacity (for standard model only) |
Charging Current (max.) | Standard Models - 1.5Amp. Long Run Models - 1Amp/2Amp/4Amp/6Amp selectable (factory default is 6Amp) |
Protection | |
Full Protection | Overload, discharge, thermal, short circuit and overcharge protection |
Surge Protection | 984 Joules/22000 Amps |
Communications and Management | |
Interface | USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
Software | PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac-based operating systems |
LCD Display/Alarm | UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators |
Audible Alarm | Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload |
Physical | |
Dimension, (D x W x H) mm | 500 x 438 x 88 |
Weight (kg) | 19.5 |
Operating Environment | |
Temperature | 0°C ~ 40°C |
Humidity | 20% ~ 90% (RH Non-condensing) |
Noise Level | <50dBA@1m |
Compliance | |
Safety/EMC/RoHS | EN62040-1-1 2003, IEC60950-1-1/EN62040-2 2006/Directive 2011/65/EU |